Before using, user must determine suitability of this product for its intended use.
• Prepare substrate by sanding and removing any dirt or coatings from surface just as you would prepare surface when using any other latex coating.
• Applicator must wear paint mask, goggles and gloves suitable for latex coatings.
• WT-102 must be mixed extremely well. Minimize contact with air as product dries fast.
• Luan: Class A or Class 1 at 125 sq. ft. per gallon, in 1 Coat or 15-16 wet mils.
• Doug Fir & Birch: Class A or Class 1 at 200 sq. ft. per gallon in two coats
• MDF: Class B or Class 2 at 150 sq. ft. per gallon in one coat
• Nylon Netting: NFPA 701 and CA Title 19 Roll application at 130 sq. ft. per gal. in two coats
• Closed Cell Polystyrene (EPS) Type 1 Closed Cell Foam Class B Apply with airless sprayer with a 415-spray tip, brush or ½” nap roller in 1 application at 22 wet mil thickness to all exposed areas.
• OEM Manufacturing for custom applications – contact manufacturer for specifics